Thông tin chung

  English

  Đề tài NC khoa học
  Bài báo, báo cáo khoa học
  Hướng dẫn Sau đại học
  Sách và giáo trình
  Các học phần và môn giảng dạy
  Giải thưởng khoa học, Phát minh, sáng chế
  Khen thưởng
  Thông tin khác

  Tài liệu tham khảo

  Hiệu chỉnh

 
Số người truy cập: 107,101,478

 Visualization of Combustion in Polymer-Electrolyte-Membrane Fuel Cell - Mechanism on Abrupt Change from Moderate to Accidental Scale-
Tác giả hoặc Nhóm tác giả: M. Ngo, K. Ito, H. Nakajima, T. Karimata, and T. Saitou
Nơi đăng: 242nd ECS meeting, Atlanta, Georgia, USA; Số: MA2022-02;Từ->đến trang: 1407-1407;Năm: 2022
Lĩnh vực: Khoa học công nghệ; Loại: Báo cáo; Thể loại: Quốc tế
TÓM TẮT
This study is focused on elucidating the catalytic combustion phenomenon in proton-exchange membrane fuel cells. A visualization cell and an infrared (IR) camera are used to capture the thermal behavior under combined chemical and mechanical accelerated stress conditions in situ. A 3.4 cm2 catalyst coated membrane (CCM) embedded in the cell is subjected to a relative humidity (RH) cycling test at atmospheric pressure and a cell temperature of 80 °C under open-circuit voltage (OCV) conditions. The temperature distribution on the gas diffusion layer surface at the cathode is captured using a high-transmittance glass window (ZnS window). Continuous IR imaging revealed a hot spot at ca. 500 RH cycles, suggesting the existence of a pinhole in the degraded CCM and the occurrence of catalytic combustion there. The occurrence of the hot spot coincides with the time at which the electrochemical indicators detect membrane failure, i.e., hydrogen crossover rate, OCV. Furthermore, the post mortem analysis revealed a 105-micrometer diameter pinhole, the position of which matched that of the hotspot. An accidental combustion during the durability test could cause the formation of a pinhole. This pinhole is responsible for the rapid increase in the hydrogen crossover rate as well as the significant decrease in the OCV at 500 RH cycles until the end of the durability test.
ABSTRACT
This study is focused on elucidating the catalytic combustion phenomenon in proton-exchange membrane fuel cells. A visualization cell and an infrared (IR) camera are used to capture the thermal behavior under combined chemical and mechanical accelerated stress conditions in situ. A 3.4 cm2 catalyst coated membrane (CCM) embedded in the cell is subjected to a relative humidity (RH) cycling test at atmospheric pressure and a cell temperature of 80 °C under open-circuit voltage (OCV) conditions. The temperature distribution on the gas diffusion layer surface at the cathode is captured using a high-transmittance glass window (ZnS window). Continuous IR imaging revealed a hot spot at ca. 500 RH cycles, suggesting the existence of a pinhole in the degraded CCM and the occurrence of catalytic combustion there. The occurrence of the hot spot coincides with the time at which the electrochemical indicators detect membrane failure, i.e., hydrogen crossover rate, OCV. Furthermore, the post mortem analysis revealed a 105-micrometer diameter pinhole, the position of which matched that of the hotspot. An accidental combustion during the durability test could cause the formation of a pinhole. This pinhole is responsible for the rapid increase in the hydrogen crossover rate as well as the significant decrease in the OCV at 500 RH cycles until the end of the durability test.
[ manh_kyushu u_ecs conference on 11 october 2022 in us.pptx ]
© Đại học Đà Nẵng
 
 
Địa chỉ: 41 Lê Duẩn Thành phố Đà Nẵng
Điện thoại: (84) 0236 3822 041 ; Email: dhdn@ac.udn.vn